installation before beginning to ensure a high quality






Monster Tower Light Bar
Installation Instructions
and Owners Manual
Phone: 877-77-Tower or 770-410-3451
Monster Tower, Inc.
Fax: 877-232-6538 or 770-234-3833
1205 Alpha Drive
www.MonsterTower.com
Alpharetta, GA 30004
Support@MonsterTower.com
THANK YOU FOR YOUR BUSINESS. IF YOU ARE NOT COMPLETELY SATISFIED IN ANY WAY
WITH YOUR NEW LIGHT BAR, PLEASE CONTACT US. Our entire purpose as a company is to
offer great products at affordable prices that our customers love.
Please take a few minutes to read the installation instructions and become familiar with the
wiring and installation before beginning to ensure a high quality, trouble free installation and
use. If you have any questions during your installation give us a call at 877-77-Tower or e-mail
Support@MonsterTower.com
NOTES ON INSTALLING AND USING YOUR NEW TOWER LIGHTS
Tower lights will reach a high temperature when operating. Do not touch or wash the
lights for 10 minutes after use.
Only use “H3 55W 12V” Halogen light bulb and fuse for replacement. These are available
online at bulbs.com and most auto parts stores. Anything exceeding 55W/15Amp could
result in damage to your boat wiring.
Use appropriate gauge wire for all connections. Consult wiring diagrams & wire sizing
chart for details.
Use of a relay is highly recommended unless you confirm your switch can support a 20
amp load. An inline fuse is required (see wiring diagram)
Tower lights are not for wakeboarding at night, which is illegal in every state.
There are countless methods of wiring lights. Please contact a marine wiring specialist if
you need assistance. We have provided the most complete information we have found
within this document.
It is highly recommended that you use a relay and a fuse with each set of lights.
Page 1 of 5
MTLB-V1-051506 Copyright 2002-2006, Monster Tower, Inc
Monster Beam Tower Lights Parts List
Item Qty Description
1 2 Tower Collar Bracket
2 4 Delrin Collar Inserts
3 1 Tower Light Bar with Four Lights
4 4 M8x25 Socket Head Cap Screws
Standard “Two plus two” light bar with two facing forward and two facing rear
Light bar with four lights facing the same direction by turning around the end lights
Lead wires with common ground (Black) and Red and Blue Power leads
Page 2 of 5
MTLB-V1-051506 Copyright 2002-2006, Monster Tower, Inc
Attaching the light bar to the tower
Attach the Collar Bracket (Item 1) to the tower using M8x25 bolts (Item 4) and the Collar Inserts
(Item 2) that matches your size tower (2-1/2” are provided for Monster Towers and a universal kit
with 1-1/2”, 1-5/8”, 1-3/4”, 1-7/8”, 2” and 2-1/4” are provided for other towers).
Turning the lights to all face the same direction
You can easily turn the outside lights so all four lights face in the same direction.
1) Remove Light Bolts on each end of the light
2) Remove End Cap
3) Remove Bracket Bolts to remove the bracket
4) Remove threaded bar and insert into the opposite railing
5) Re-assemble and align the center hole of the bracket where the wire exits the tube
IMPORTANT – Tighten bracket bolts BY HAND, then 1⁄4 of a turn ONLY or the
threads may be stripped.
Bracket Bolt Light Bolt
End Cap
Page 3 of 5
MTLB-V1-051506 Copyright 2002-2006, Monster Tower, Inc
Wiring Recommendations
We recommend using a SPST relay (Single Pole Single Throw) with your switch and appropriate
gauge wiring. Relays are readily available at auto parts stores, Radio Shack, and online at
www.PartsExpress.com (part number 330-070) and cost under $5 each. Parts Express also has an
excellent technical support department. There are many sources and links for wiring 12V lights at
www.diyTower.com that you may want to reference.
Not using a relay could cause excessive heat in the wiring and switch and create a risk of fire
because of the amount of power being drawn by the high output lights. A relay works by using a
switch to run 12 volts to the relay. The relay acts as an electrical switch that activates and draws
power straight from the battery connection and sends it to the lights or accessory. The power
actually going to the switch never gets routed to the lights.
See diagrams and wiring size chart at the end of this document for options & details.
Running Wires Through The Tower
The following is specific to running wires on a Monster Tower, otherwise consult your tower
installation manual or provider for instructions on running wire inside your tower.
When you add speakers or lights to your Monster Tower, you can hide the wires inside of the rear
legs of the tower as well as in the straight cross member of the top section. Since the mating
parts insert 1⁄2” inside each end of the rear leg you can drill 1” away from the weld lines. For the
top section cross member you will need to place the hole 3” from the weld line to clear the
rotating collar assembly. The hole size will depend on what size wire you are running and how
many items you need to wire. The maximum hole size we recommend is 1⁄2” but normally smaller
is all that is needed.
We recommend covering the exposed wiring with 3/8” or 1/2” wiring loom and electrical tape for a
professional, watertight appearance.
1”
1⁄2”
For learning more about tower accessories, we highly encourage you to visit the “Boats and
Accessories” discussion boards at www.Wakeboarder.com and www.WakeWorld.com and
www.diyTower.com.
Page 4 of 5
MTLB-V1-051506 Copyright 2002-2006, Monster Tower, Inc
Monster Tower, Inc Warranty
Monster Tower warrants this product (not including the bulbs) against manufacturers defects for a
period of five (5) years. Anodized surfaces are specifically excluded, as their care and use cannot
be controlled by the manufacturer. Any modifications or improper use, not approved in writing by
Monster Tower, shall void this warranty. Monster Tower is not responsible for personal injury or
damage to the boat caused by the use of this product. Monster Tower’s obligation under this
warranty shall not include any transportation charges or costs of installation or any liability for
direct, indirect or consequential damages resulting from delay or improper installation. Your time
would be better spent wakeboarding then reading warranty details. If you need to make a
warranty claim contact Monster Tower at 877-77-Tower to receive a return authorization number
which is required for all claims. Defects must be reported within 30 days of discovery.
- Wiring Option Diagrams and Wire Sizing Chart Follows -
Page 5 of 5
MTLB-V1-051506 Copyright 2002-2006, Monster Tower, Inc
Option 1
Single Switch w/ Relay
See Note A
Wire Nut
Switch
Not
Used
12V Fuse Block
Negative (Ground)
Buss Bar
Typically Found Under Dash
NOTE "A"
NOTE: See Wire Sizing Chart to determine proper gauge
wire for each connection. Each PAIR of lights draws 10
Bosch Standard
Amps (20 Amps total for single relay). Each switch used
Relay (MR76)
in conjunction with a relay will draw less than 4 Amps.
(Note: Radio Shack 12V
Wire sizes apply to both Power & Ground wires.
Automotive Relay (275-226)
is same less unused contact 87a) -
+
NOTE: In this configuration, use 20 Amp Fuse for Relay &
12 Volt Battery
4 Amp Fuse for Switch.
Option 2
Dual Switches w/ Relays
See Note A
Switch
Switch Not
Used
Not
Used
12V Fuse Block
Negative (Ground)
Buss Bar
Typically Found Under Dash
NOTE: See Wire Sizing Chart to determine proper
gauge wire for each connection. Each PAIR of lights
draws 10 Amps per relay. Each switch used in
-
+
NOTE "A" conjunction with a relay will draw less than 4 Amps.
Wire sizes apply to both Power & Ground wires. 12 Volt Battery
Bosch Standard
Relay (MR76)
(Note: Radio Shack 12V NOTE: In this configuration, use 10 Amp Fuse for Relays &
Automotive Relay (275-226) 4 Amp Fuse for Switches.
is same less unused contact 87a)
Option 3
Single Switch w/o Relay
Wire Nut
Switch
Rated for 20+ Amps
12V Fuse Block
Negative (Ground)
Buss Bar
Typically Found Under Dash
NOTE: See Wire Sizing Chart to determine proper
gauge wire for each connection. Each PAIR of lights
draws 10 Amps therefore, each single switch used
without a relay will draw up to 20 Amps. Wire sizes
apply to both Power & Ground wires.
NOTE: In this configuration, use 20 Amp Fuse for Switch.
-
+
12 Volt Battery
Option 4
Dual Switches w/o Relays
Switch Switch
Rated for 10+ Amps Rated for 10+ Amps
12V Fuse Block
Negative (Ground)
Buss Bar
Typically Found Under Dash
NOTE: See Wire Sizing Chart to determine proper
gauge wire for each connection. Each PAIR of lights
draws 10 Amps therefore, each switch used without
a relay will draw up to 10 Amps. Wire sizes apply to
both Power & Ground wires.
-
+
NOTE: In this configuration, use 10 Amp Fuse for each Switch.